Rafter Construction 
Laying out a rafter and cutting it for installation
Rubric Code: Q9W74B
Ready to use
Public Rubric
Subject: Vocational  
Type: Writing  
Grade Levels: 9-12, Undergraduate

Powered by iRubric Rafter construction
  Needs Improvement

0 pts

Fair

2 pts

Good

3 pts

Excellent

4 pts

calculations.

all correct.rise run.
rafter length.slope.

Needs Improvement

calculations not correct.not accurate.
Fair

Some calculations are correct. Rise, Run, and Slope are accurate.Rafter length incorrect.
Good

Most calculations are correct. Rise, Run, and Slope are accurate Some .Rafter lengths correct.
Excellent

All calculations are correct. Rise, Run, and Slope are accurate.ALL Rafter lengths correct.
Layout

Layout Common Rafter
Apply Basic Math Princicpals
Layout Markin and Measuring Tools

Needs Improvement

No effort shown

Rafter is not laid out properly. Will not work if cut
Fair

Lays out the rafter but relies on the instructor. Very few correct correct.
Good

Is able to layout the rafter with minimal assistance
Most of the rafter is laid out properly will work with minimal adjustment.
Excellent

Is able to layout the rafter without instructional support accuratley
Bird's mouth, plumb cut, tail cut, and line length is accurate.
cutting

safe accurate cutting

Needs Improvement

little effortshown

no cuts made or
cuts are not straight. Rafters will not fit properly. properly.
Fair

some of the cuts are accurate. Will need to be modified to fit properly.Some of the rafter was cut correctly.
Good

most of the cuts are accurate. Will work with minimal modification.Most was cut correctly.
Good workmanship.
Excellent

All cuts are made on the correct side of the line and accurate. A hand saw was used.
install

ASSEMBLY

Needs Improvement

Roof frame was improperly assembled and must be rebuilt.
Nothing assembled.
no Participation
Fair

Roof frame was improperly assembled and must be rebuilt. Poor workmanship.nails are out of position.
little holding strength.
Good

nails are located for minimum strength.
Pride in work
Excellent

Nails are located to acquire maximum holding power, and driven cleanly into rafter.Neatly done.
quality workmanship.
Great pride in work
Safety`

1.A.01a Identify Safety Requirements

Needs Improvement

no effort shown.
no participation
Fair

Relies on the instructor for guidance
Good

Requires minimal assistance
Excellent

Has and uses all the the required safety equipment personal and tool



Keywords:
  • Construction Technology Grades 11 & 12

Subjects:

Types:





Do more with this rubric:

Preview

Preview this rubric.

Edit

Modify this rubric.

Copy

Make a copy of this rubric and begin editing the copy.


Print

Show a printable version of this rubric.

Categorize

Add this rubric to multiple categories.

Bookmark

Bookmark this rubric for future reference.
Assess

Test run

Test this rubric or perform an ad-hoc assessment.

Grade

Build a gradebook to assess students.

Collaborate

Apply this rubric to any object and invite others to assess.
Share

Publish

Link, embed, and showcase your rubrics on your website.

Email

Email this rubric to a friend.

Discuss

Discuss this rubric with other members.
 

Do more with rubrics than ever imagined possible.

Only with iRubrictm.

n202